JUMPER F.O. OM3 125 2LC(PC) 2LC(PC) 002M HOPLCOM3020LC253 (BRAND-REX)
FibrePlus Optical Patch Cord
APPLICATION Fiber Optic Patch Cords are designed to interconnect, or cross-connect fiber networks within structured cabling systems for data centers, Broadband CATV, Passive Optical Networks (PON), WDM or DWDM multiplexing, FTTH, and voice services in ATM and SONET metropolitan and access networks. Common connector patch cord configurations in 1, 2, 3, 5, and 10-meter lengths are stocked for quick service, while hybrid connector combinations, custom lengths, low loss, and custom color patch cords are made to order. Contact customer service for details.
FEATURES • Available in simplex, duplex, and pigtail configurations • LC, LC Unibody with SPECTRO-LINK™ Technology, LC/APC, SC, SC/APC, ST, FC, and FC/APC connector options • Stock and make-to-order • TIA compliant color-coded connectors and boots • Cable jacket and boots color-coded for easy ID of fiber • Fiber options: OS2, OM1, OM3, OM4, and OM5 • 100% tested for insertion loss and single-mode for return loss • LC Unibody connectors have patented reversible polarity features, allowing polarity changes in the field without tools • The LC Unibody design with push/pull grips and 2.0 mm round cable is ideal for high-density applications • Patch cords include a Limited Lifetime Warranty when used with other Leviton cabling and installed by a Leviton certified contractor • Other jacket colors available as custom with MOQ and lead time applicable • Custom configurations via Leviton.com/mto
SPECIFICATION Patch cords shall be compliant with ANSI/TIA-568.3-E. Standard insertion loss shall be a maximum of 0.25 dB for multimode and single-mode. Low loss shall be a maximum of 0.15 dB for multimode and single-mode connectors. Multimode return loss shall be greater than 26 dB and greater than 50 dB for single UPC mode connectors. Single-mode angled physical contact connectors (APC) shall have a minimum of 60 dB return loss. Patch cords shall have a pull force of at least 50 N per IEC 61300-2-4. Connector durability shall be greater than 500 matings for both multimode and single-mode. Patch cord shall be LSHF (Low Smoke Halogen Free), HFFR-LS (Halogen-Free Flame-Retardant LowSmoke) rated. Patch cords shall be individually packaged with part numbers, descriptions, optical performance, code 39 barcode part number printed on each package, and QR code to access supporting documentation. Patch cords shall include wrap labels including length, end designation, and serial number, providing traceability to factory collected test data.
DESIGN CONSIDERATIONS • LSHF (Low Smoke Halogen Free), HFFR-LS (HalogenFree Flame-Retardant Low-Smoke) rated • All connectors have precision pre-radiused or pre-angled zirconia ferrules supporting consistent End Face Geometry (EFG) • Single-mode available in UPC and APC polish • FC and ST connectors have metal bodies • Duplex clips included with LC and SC duplex configurations • Bend-insensitive glass (OS2, OM3, and OM4 and OM5)
STANDARDS & REGULATIONS • ANSI/TIA-568.3-E • ISO/IEC 11801-1 • Fiber Optic Connector Intermatability Standards (FOCIS) • TIA-604-10B (LC) • TIA-604-3B (SC) • TIA-604-2B (ST) • TIA-604-4B (FC) End face geometry: • IEC 61755-3-1 (UPC/PC) • IEC 61755-3-2 (APC) Fiber compliance: • OS2: IEC 60793-2-50, ITU-T G.657.A1 • OM1: IEC 60793-2-10 • OM3: IEC 60793-2-10, ITU-T G.651.1 • OM4: IEC 60793-2-10, ITU-T G.651.1 • OM5: IEC 60793-2-10, TIA 492AAAF, ITU-T G.651.1 Jacket flame rating: • LSZH / HFFR-LS • IEC 60332-3-24, IEC 60332-1-2 • RoHS COUNTRY OF ORIGIN China USA for LC Unibody Connector
PESO: 0.024 KGS / UNIDAD