Due to the configuration of the device, it is not recommended to use it outdoors. The equipment is type 1 action, pollution degree 2, rated impulse voltage 2500 V and overvoltage category II. An overvoltage protection device must be installed in the installation, external to the equipment.
GENERAL DESCRIPTION: CIO 22 is an on/off actuator provided with 2 triac outputs with a cutting power of 2A per output and 2 digital inputs at 230 Vac. Equipment controlled through the BUSing® Radio home automation system.
FEATURES:
Electrical control device used to control lighting and/or any other type of electrical load with a working voltage of 230V.
Each output has a cutting capacity of 2A.
A minimum power of 15W is required on the load connected to output 1, but there is no minimum value for the power of the load of output 2. In some cases, an additional load may be required.
For the control of higher power circuits, insert a contactor.
Memory of the last position in case of power failures.
Radio communication has an approximate range of 15 m.
Push button to enter programming mode.
The Center-Link device is required to carry out programming from the application.
TECHNICAL INFORMATION:
Power supply 230 Vac
Max. consumption 0.5 W
Inputs 2 low voltage digital inputs
Outputs 2 triac outputs
Cutting capacity 2 A per output
Mounting In universal mechanism box
Size 51 x 51 x 19 mm
Range approximately 15 m
Frequency 868 MHz
Max. power 7 dBm
Ambient temperature ranges:
Operation: -10 ºC to 55 ºC
Storage: -30 ºC to 60 ºC
Transport: -30 ºC to 60 ºC
Regulations:
INGENIUM declares that ref.WA482200 complies with the requirements of the RED Directive 2014/53/UE. http://ingeniumsl.com/pdf/DC_CIO22_es.pdf
OBSERVATIONS:
It is recommended to detect all the equipment of the same type before starting to program. Ensure that the
equipment being programmed is the desired one. The phase and neutral polarity must be respected in the connections to avoid damaging the equipment.